Company Info
Basic Info.
Model NO.
HS12V
Certification
RoHS, ISO9001, CE
Working Medium
R290
Heat Source Type
Air Source Heat Pump
Specification
12KW
Product Description
Energy efficiency class of A+++ reduce the energy consumption of the outdoor unit. Using smart grids (SG ready), you can also take advantage of variable electricity prices and make additional savings.
Works all the way down to minus 25 degrees, so you are guaranteed good and stable heat, even on the coldest days of the year.
Frequency controlled: The heat pump can run with different services. When the desired temperature is achieved, running it with a lower one; frequency/performance to reduce energy consumption.
With DC Inverter brushless fan motor that can be controlled so that the sound from the device reaches a satisfactory low level.
Intelligent defrosting technology that minimizes energy consumption.
Model Number | HS12V | |
Heat output at A7/W35ºC | kW | 12.22 |
Power consumptionat A7/W35ºC | kW | 2.76 |
COP A7W35 | 4.43 | |
Heat output at A2/W35ºC | kW | 9.78 |
Power consumptionat A2/W35ºC | kW | 2.68 |
COP A2/W35 | 3.65 | |
Heat output at A7/W55ºC | kW | 11.02 |
Power consumptionat A7/W55ºC | kW | 3.36 |
COP A7/W55 | 3.28 | |
Heat output at A-10/W55ºC | kW | 7.35 |
Power consumptionat A-10/W55ºC | kW | 3.20 |
COP A-10/W55 | 2.30 | |
Cool output at A35/W7ºC | kW | 9.20 |
Power consumption at A35/W7ºC | kW | 3.43 |
EER A35/W7 | 2.68 | |
Cool output at A35/W18ºC | kW | 11.07 |
Power consumption at A35/W18ºC | kW | 3.59 |
EER A35/W18 | 3.08 | |
Max operating current | A | 18 |
Power Supply | 230V/50Hz | |
Compressor | Highly twin rotary | |
Condenser | Brazed plate heat exchanger | |
Nominal flow heating medium | m3/h | 1.5~3.2 |
Internal pressure drop at nominal flow | kPa | 25 |
Nominal air flow | m3/h | 3350 |
Nominal fan output | W | 80 |
Max outlet heating medium temperature | ºC | 70 |
Refrigerant R290 filling weight | kg | 0.80 |
Dimensions (HxWxD) | mm | 1014×1060×420 |
Pipe connector | G1″ external thread | |
Net Weight | kg | 112 |
ErP Level(35ºC) | A+++ | |
ErP Level(55ºC) | A++ | |
Operating ambient temp. range | ºC | Heating -25~46 |
DHW -25~46 | ||
Cooling 10~45 | ||
Sound power level LWA | dB(A) | 60 |
The above data is tested by EN14511. A7/W35ºC means air temp. 7ºC,outlet water temp. 35ºC | ||
The Sound power level is tested by EN12102 |